Skip to content

Seal Burst Disc for TRITON Electric Shower PRD Seals Kit O Ring Rubber Valve x12

£11.28
**Free Tracked Shipping**
 Complete Seals Kit for TRITON Electric Shower (Pack of 12 Seals)

Brand new, premium quality compatible seals for your Triton electric shower. This kit includes all seals needed for the vast majority of all Triton electric showers. The burst discs can be used on both 'new style' black Triton pressure relief devices. The O-ring seals & rubber ball valves can be used on the 'old style' white Triton pressure relief devices. Please see gallery pictures for more information.  A pressure relief device (PRD) is a safety feature installed in electric showers. If heated water fails to escape through the shower head due to a blockage, the PRD will blow, thereby allowing the water to escape through an outlet pipe before it causes damage to the heating tank. ***A PRD cannot be reset once it is activated and the seal and/or PRD must be replaced.***

Kit Includes:
6 x PRD Burst Disc Seals
6 x O-Ring Seals
6 x Rubber Interior Ball Valves

Fits Models:

TRITON

Fits the vast majority of all Triton electric showers, including (but not limited to):

Agio, Alicante, Amber (All Models), Amber 1, Amber 2, Amber 3, Aquablast, Aquastorm, Aquasurge, Aquatronic (All Models), Aquatronic 1, Aquatronic 1 Plus, Aquatronic 2, Aquatronic 2 Plus, Aquatronic 2 Ultra, Aquatronic 3, Aquatronic 3 Plus, Aquatronic 3 Ultra, Aquatronic 4, Aquatronic 4 Plus, Aquatronic 4 Ultra, Aspirante, Aspirante Electric, Aspirante Electronic, Aspirante Millenium, Aspirante Millennium, Aspirante Remote, Aspirante Topaz, Aspirante Wireless, Aspirante Wireless Remote, Aspirante Xr, Aviva, Bali, Barbados, Belize, Bermuda, Bewitch, Bewitch 2, Bezique, Bezique 2, Biarritz, Biarritz 2, Biscay, Biscay 2, Biscay II, Brazillia, Cara, Carino, Caselona, Caselona 2, Caselona 3, Caselona II, Collections, Colourwave, Colourwave Remote, Coral, Delta, Desire, Dominica, Enchant, Enlight, Enrich, Entice, Etana, Excite, Excite Eco, Forte, Hawaii, Hawaii 2, Inscriptions, Ivory, Ivory (All Models), Ivory 2, Ivory 3, Ivory 4, Ivory 4 MK2, Ivory III, Jade, Jade (All Models), Jade 2, Jade 3, Jade II, Jade III, Jewel, Kito, Madrid, Madrid 2, Marbella, Martinique, Miami, Millenium, Millenium Care, Millennium Care, Millennium Thermostatic, Monaco, Opal, Opal (All Models), Opal 2, Opal 3, Osiris, Passion, Perea, Perluso, Pietra, Plasma, Prostyle Plus, Rally, Rapide, Rapide 2, Rapide 2 Plus, Rapide 3, Rapide 3 Plus, Rapide 4, Rapide 4 Plus, Rapide R1, Rapide R2, Rapide R3, Safeguard, Safeguard Care, Safeguard Care Pumped, Safeguard Plus, Safeguard Pumped, Salsa, salsa MK2, Sambada, Serano, Seville, Shannon, Spellbind, Spirit, T100 XR, T100E, T100e Care, T100e Care Plus, T100e Care Thermostatic, T100e Thermostatic Care, T100EM Care, T100i, T100si, T100XR, T150Z, T150Z Pumped, T300i, T300Si, T300si Remote, T300si Wireless, T50, T50i, T55i, T60i, T60si, T70, T70GSI, T70I, T70Si, T70xr, T70Z, T75, T80, T80 XR, T80GSI, T80i, T80Si, T80SI Extra, T80SI Pumped, T80xr, T80xr Eco, T80Z, T80z Fast Fit, T80Z MK2, T80z Slimline, T80Z Thermostatic, T90 (All Models), T900PI, T90i Pumped, T90SI, T90xr, Topaz (All Models), Topaz T100i, Topaz T100si, Topaz T200i, Topaz T80i, Topaz T80SI, Touch, Trance, Trance 2, Trance MK2, TX7000, TX7000i, TX7500i, TX8500I, W7000, W8500, Wickes Aquatronic 2, Wickes Aquatronic 4, Wickes MK1, Wickes MK2, Wickes W8500, Zante, Zante 2, Zante 3, Zante II, Zante III + many more...


How To Install:

To install the burst disc seals, first remove the shower hose & unscrew the outlet pipe. When you've removed the screws, twist & pull to remove and you'll find the PRD, which is attached to the outlet pipe with 2 screws. Unscrew from pipe & remove old burst disc. Push the new burst disc on firmly, then press PRD into place & screw on to outlet pipe. Refit hose & cover. Set the temperature of your shower to cold before you run it for the first time after replacing the burst disc to allow the heating tank to refill, ensuring you don't damage the elements.

To install the o-ring & ball valve seals, first remove the shower hose & unscrew the outlet pipe. When you've removed the screws, twist & pull to remove and you'll find the PRD, which is attached to the outlet pipe with 2 screws. Unscrew from pipe & remove seal. Ensure the ball valve is inside the PRD & push the o-ring on firlmy, then press PRD into place & screw on to outlet pipe. Refit hose & cover. Set the temperature of your shower to cold before you run it for the first time after replacing the burst disc to allow the heating tank to refill, ensuring you don't damage the elements.

***Please note: all dimensions indicated in this ad are approximate and may vary slightly from indicated measurements. They are included as a guide to assist you in selecting the right part for your machine***

This product is is designed to be compatible with Triton machines and is not the original part. The name, model names and any part numbers of the original manufacturer(s) have been used for reference purposes only and are in no way associated with the original manufacturer.